( BlinTux | 2017. 07. 15., szo – 22:49 )

Nézegettem egy kis logot!

Homeassistanban ez látszik, amikor áram alá helyezem a kapcsolót:

INFO:hbmqtt.broker:Connection from 192.168.1.4:8395 on listener 'default'

Azt mondjuk nem értem mi az a 8395-ös port, sehol nincs ilyen beállítva. Az MQTT 1883-on megy.
A kapcsolón lévő SW is logol, ott ez látszik:

00:00:10 mDNS: Initialized
00:00:10 HTTP: Webserver active on sonoff-2.local with IP address 192.168.1.4
00:00:12 MQTT: Attempting connection...
00:00:13 MQTT: Connected
00:00:13 MQTT: tele/sonoff2/LWT = Online (retained)
00:00:13 MQTT: cmnd/sonoff2/POWER =
00:00:13 MQTT: tele/sonoff2/INFO1 = {"Module":"Sonoff Basic", "Version":"3.9.22", "FallbackTopic":"home-assistant-2", "GroupTopic":"sonoffs"}
00:00:13 MQTT: tele/sonoff2/INFO2 = {"WebserverMode":"Admin", "Hostname":"sonoff-2", "IPaddress":"192.168.1.4"}
00:00:13 MQTT: tele/sonoff2/INFO3 = {"Started":"Power on"}
21:33:06 MQTT: stat/sonoff2/RESULT = {"POWER":"ON"}
21:33:06 MQTT: stat/sonoff2/POWER = ON
21:33:13 MQTT: tele/sonoff2/STATE = {"Time":"2017-07-15T21:33:13", "Uptime":0, "POWER":"ON"}
21:33:13 MQTT: tele/sonoff2/SENSOR = {"Time":"2017-07-15T21:33:13", "DHT11":{"Temperature":26.0, "Humidity":34.0}}

Tehát csatlakozik a brókerhez, de Homeassistant paneljén mégsem változik a kapcsoló állása, a fentebb írt configgal.