/lib/nut/usbhid-ups -a legrand -DDD:
62.075810 [D2] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x32, Offset: 16, Size: 1, Value: 1
62.075819 [D3] Report[buf]: (4 bytes) => 32 00 00 19
62.075827 [D2] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Feature, ReportID: 0x32, Offset: 18, Size: 1, Value: 0
62.075836 [D3] Report[buf]: (4 bytes) => 32 00 00 19
62.075844 [D2] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Feature, ReportID: 0x32, Offset: 20, Size: 1, Value: 1
62.075853 [D3] Report[buf]: (4 bytes) => 32 00 00 19
62.075860 [D2] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x32, Offset: 21, Size: 1, Value: 0
64.077533 [D1] upsdrv_updateinfo...
64.077554 [D1] Not using interrupt pipe...
64.077562 [D1] Full update...
64.077703 [D3] Report[get]: (3 bytes) => 18 43 09
64.077712 [D2] Path: UPS.PowerConverter.Input.Voltage, Type: Feature, ReportID: 0x18, Offset: 0, Size: 16, Value: 6.7e-05
64.077856 [D3] Report[get]: (3 bytes) => 20 88 00
64.077869 [D2] Path: UPS.BatterySystem.Battery.Voltage, Type: Feature, ReportID: 0x20, Offset: 0, Size: 16, Value: 0.000136
64.078038 [D3] Report[get]: (2 bytes) => 34 64
64.078051 [D2] Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x34, Offset: 0, Size: 8, Value: 100
64.078221 [D3] Report[get]: (3 bytes) => 35 0b 0a
64.078232 [D2] Path: UPS.PowerSummary.RuntimeToEmpty, Type: Feature, ReportID: 0x35, Offset: 0, Size: 16, Value: 2571
64.078362 [D3] Report[get]: (3 bytes) => 1b 92 09
64.078371 [D2] Path: UPS.PowerConverter.Output.Voltage, Type: Feature, ReportID: 0x1b, Offset: 0, Size: 16, Value: 0.000146
64.078489 [D3] Report[get]: (2 bytes) => 1e 0e
64.078497 [D2] Path: UPS.OutletSystem.Outlet.PercentLoad, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 8, Value: 14
64.078656 [D3] Report[get]: (4 bytes) => 32 00 00 19
64.078672 [D2] Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x32, Offset: 16, Size: 1, Value: 1
64.078681 [D3] Report[buf]: (4 bytes) => 32 00 00 19
64.078694 [D2] Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Feature, ReportID: 0x32, Offset: 18, Size: 1, Value: 0
64.078703 [D3] Report[buf]: (4 bytes) => 32 00 00 19
64.078710 [D2] Path: UPS.PowerSummary.PresentStatus.Charging, Type: Feature, ReportID: 0x32, Offset: 20, Size: 1, Value: 1
64.078717 [D3] Report[buf]: (4 bytes) => 32 00 00 19
64.078724 [D2] Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x32, Offset: 21, Size: 1, Value: 0
A Voltage 0.000136 !!!?
viszont:
upsc legrand
Error: Connection failure: Cannot assign requested address
:(